Type: WRG-40/2
Output voltage:0--40kv
current: 0--2mA
Stability: <1%
Ripple rate: <1%
Accuracy of kV meter: 1%
mA meter:1%
Working style: short term working(1 hr) A 31/2digital mA meter which can working on the HV output port is provided
Inner isolated: filled with isolating oil
HV tower (body): Ø128X290mm, 3.8kg
Controller: 290X210X270mm, 3kg
Usage: portable
|
|
|
Type: WRG-60/2
Output voltage: 0--60kv
current: 0--2mA
Stability:<1%
Ripple rate: <1%
Accuracy of kV meter:1%
mA meter:1%
Working style:short term working(1 hr)
A 31/2digital mA meter which can working on the HV output port is provided
Inner isolated: filled with isolating oil
HV tower (body):Ø128X290mm, 3.8kg
Controller: 290X210X270mm, 4kg
Usage: portable
|
|
|
Type: WRG-60/3
Output voltage: 0--60kv
current: 0--3mA
(Other items are same as above)
|
|
Type: WRG-120/2.5
Output voltage:0--120kv
current:0--2.5mA
Stability:<1%
Ripple rate: <1%
Accuracy of kV meter:1%
mA meter:1%
Working style: short term working(1 hr)
A 31/2digital mA meter which can working on the HV output port is provided
Inner isolated: filled with isolating oil
HV tower (body):Ø140X400mm, 6kg
Controller:330X210X270mm, 6.3kg
Usage: portable
|
|
|
Type: WRG-200/2.5
Output voltage: 0--200kv
current: 0--2.5mA
Stability:<1%
Ripple rate: <1%
Accuracy of kV meter:1%
mA meter:1%
Working style: short term working(1 hr)
A 31/2digital mA meter which can working on the HV output port is provided
Inner isolated: filled with isolating oil
HV tower (body):Ø150X700mm, 18kg
Controller: 380X210X320mm, 10.3kg
Usage: portable
|
|
|
Type: WRG-300/2
Output voltage: 0--300kv
current: 0--2mA
Stability: <1%
Ripple rate:<1%
Accuracy of kV meter:1%
mA meter: 1%
Working style: short term working(1 hr)
A 31/2 digital mA meter which can working on the HV output port is provided
Inner isolated: filled with isolating oil
HV tower (body):Ø240X1200mm, 27kg
Controller: 400X210X320mm, 16kg
Usage: portable
|
|
|
Type: WRG-300/3
Output voltage: 0--300kv
current:0--2mA
|
|
Type: WRG-400/3
Output voltage:0--400kv
current:0--2mA
|
|
Type: WRG-600/2, 600/4, 600/10
Output voltage:0--600kv
current:0--2mA, 4mA, 6mA
|
|
High-stability generators
WRG-W100/2: 100kV, 2mA
WRG-W100/4:100kV, 4mA
WRG-W200/2: 200kV, 2mA
WRG-W200/4: 200kV, 4mA
Output high voltage stability, ripple rate and measure accuracy can reach
these levels: 0.5%, 0.2%, 0.1%, 0.05%, 0.02%
|
|
*Ultra high voltage systems, rated to 1200kV, 2000kV and 2400kV are supplied.
**For DC Wet or Pollution tests which demand long duration, high peak current pulses special systems (such as 250kV/400mA, peak current up to 2A)are supplied.
|